FD2705R
Loop Powered.2000 series protocol.Area c ...
Loop Powered.2000 series protocol.Area coverage up to 600 m².2000 series protocol.Range from 5 to 50 m and 50 to 100 m.Up to ceiling heights of 25 m.Low current consumption
Look detailLoop Powered.2000 series protocol.Area c ...
Loop Powered.2000 series protocol.Area coverage up to 600 m².2000 series protocol.Range from 5 to 50 m and 50 to 100 m.Up to ceiling heights of 25 m.Low current consumption
Look detailOne-pipe air sampling system.Conventiona ...
One-pipe air sampling system.Conventional or analogue addressable detectors.Test hole on cover.Simple installation.Sensitive flow indication.Simple service and maintenance
Look detailIn- and outputs individually programmabl ...
In- and outputs individually programmable on a single loop address.Versatile input structure with full line supervision.Normally open or closed relay operation.Magnetically latched output relays maintain relay positions in case of power failure.Loop powering saves on external supply and installation costs.Easy numeric addressing avoids addressing errors
Look detailLow profile design.Reliable contact syst ...
Low profile design.Reliable contact system.Possibility of locking the detector to the base
Look detailIf short pressed “SILENCING” mode is act ...
If short pressed “SILENCING” mode is activated. Green LED flashes, buzzer and panel activation are disabled for 5min;.If pressed for more than 5 seconds “TEST” mode is activated. In this case green, red and yellow LED’s are activated. Panel and buzzer are activated, too. After 6 seconds gas detector emits 2 short sounds and leaves “TEST” mode
Look detailSensitivity selectable from the control ...
Sensitivity selectable from the control panel – High/Normal/Middle/Low.Class for the temperature part – A1R (according to EN54-5).Day/Night mode.Low profile design.LED indication with 360° visibility.Version with built in isolator – SensoIRIS M140 IS
Look detailSensitivity level selectable from the co ...
Sensitivity level selectable from the control panel – High/Normal/Middle/Low.Day/Night mode.Low profile design.Led indication with 360° visibility.EN54-7 Certified.Version with built in isolator – SensoIRIS S130 IS
Look detailCan work as a fixed temperature or rate ...
Can work as a fixed temperature or rate of rise detector.Class selctable from the control panel – A1R, A2S, BS.Low profile design.LED indication with 360° visibility.EN54-5 Certified.Version with built-in isolator – SensoIRIS T110 IS